Installation and commissioning of hydraulic hose criming machine
Transportation: The hydraulic hose criming machine is suitable to be carried by a forklift, and the bottom of the hydraulic hose criming machine is stressed. The hydraulic hose criming machine is strictly prohibited to be inverted. It is forbidden to lift the hydraulic hose criming machine head and the parts of the motor and electrical box.
Installation: The hydraulic hose criming machine needs to be placed horizontally on a stable foundation and grounded.
Oil filling: Open the fuel tank cap, and add 68 # anti-wear hydraulic oil to the fuel tank to the 2/3 position of the oil level gauge.
Power connection: Connect the power cord to the power supply specified by the
hydraulic hose criming machine, start the motor and observe the direction of rotation. The direction of rotation of the motor should be the same as that of the motor If the direction of the motor is different from the marked direction, please change the position of the two power cables.
Micrometer: Used to adjust the amount of shrinkage of the
crimping hose, press 1mm more in the counterclockwise half cycle and 1mm less in the clockwise half cycle.
Pressure adjustment: The maximum pressure of the hydraulic hose criming machine system is 31.5Mpa, which is adjusted by the relief valve, which increases the clockwise adjustment pressure and decreases the counter-clockwise adjustment pressure (it is adjusted at the factory, and can be adjusted if necessary).
Adjustment of mold opening speed: The speed of mold opening speed is controlled by the diverter valve, adjusting clockwise, opening speed is increased, adjusting counterclockwise, opening speed is slowed down, but too fast opening speed will increase noise. The best value is not more than 10Mpa (it has been adjusted at the factory, and it can be adjusted if necessary).